Study on open-cycle carbon dioxide refrigerator for movable mine refuge chamber

期刊

APPLIED THERMAL ENGINEERING
卷 52, 期 2, 页码 304-312

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2012.12.014

关键词

Carbon dioxide; Open-cycle refrigerator; Mine refuge chamber; Capillary tube; Heat exchanger

资金

  1. National Natural Science Foundation of China [50890181, 51076160]
  2. Xinjiang125 Major Projects [201130112]

向作者/读者索取更多资源

For a movable mine refuge chamber, the refrigeration system is important to remove miners' body heat and the heat input from the hot outside environment The refrigeration cycle has been changed from closed cycle using traditional Freon refrigerant to open cycle using high pressure carbon dioxide. The open cycle refrigerator has no compressor and it consumes no electricity. The open system is composed of a Joule-Thomson (JT) valve, an evaporator, a capillary heat exchanger, a pneumatic blower and several connecting tubes. For the evaporator, a stainless steel heat exchanger as well as a smooth tube heat exchanger were designed and tested and compared with a conventional finned tube copper heat exchanger. The tests show that the performance of cooling and dehumidification is nearly the same for the three heat exchangers. Because the stainless heat exchanger has higher strength and lower cost than the two others, it might be the best choice in actual applications. A long capillary tube heat exchanger is used to decrease the carbon dioxide pressure from around 20-35 bar to 5 bar, and at the same time the gas is kept above a temperature of 10 degrees C by making use of the sensible heat (C) 2012 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据