4.7 Article

Thermal analysis of a combustion chamber surrounded by deposits in an HCCI engine

期刊

APPLIED THERMAL ENGINEERING
卷 50, 期 1, 页码 81-88

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2012.06.004

关键词

Combustion chamber deposit; Thermal analyses; HCCI; Finite element technique

向作者/读者索取更多资源

In this study, temperature distribution in a CCD coated piston used in an HCCI engine was investigated and was guided by existing experimental results. A model based on experimental observations obtained from the experiments at Shell research center was developed by using finite element technique to investigate 3D thermal analyses for both clean and deposited piston. Effect of the CCD thickness on the temperature distribution was analyzed by comparing the results from the clean piston and deposited one. It was observed that the deposited surface temperature increases with increasing the thickness in a decreasing rate. Both aluminum and steel piston compared with each other in respect to the maximum temperature for the same CCD thicknesses, which were tn = 9 and tm = 30 in micro meters. Compared to the clean piston, maximum temperature on the top surface of the aluminum and steel metals diminish 6 degrees C and 9 degrees C respectively, because of CCD's relatively low heat transfer coefficient. (c) 2012 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据