4.7 Article Proceedings Paper

Self-compensating characteristic of steam water mixture at low mass velocity in vertical upward parallel internally ribbed tubes

期刊

APPLIED THERMAL ENGINEERING
卷 30, 期 16, 页码 2370-2377

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2010.06.001

关键词

Vertical upward parallel tubes; Self-compensating characteristic; Low mass velocity; Internally ribbed tube; Supercritical pressure once-through boiler

向作者/读者索取更多资源

This paper presents an experimental investigation on Self-Compensating Characteristic (SCC) in vertical upward parallel tubes with low mass velocity of steam-water two-phase mixture. A physical model was built up using parallel internally ribbed tubes. A method called Differential Pressure Substitute was used to measure two-phase flow parameters. The results indicated that the SCC of vertical upward parallel tubes is caused by combined action of frictional pressure drop and gravitational pressure drop. The mass velocity in the tube with lower heat flux decreases first, and then increases with an increase in quality. The uneven heat fluxes among tubes are the main reasons that cause mass velocity differentials. Greater uneven heating ratio enhances the SCC in low quality region and weakens it in high quality region. The SCC has different variation rules in different pressure region. In the sub-critical pressure region, rising pressure weakens the SCC when quality is low and enhances it when quality is high. In near-critical pressure region, the mass velocity varies monotonically and slowly with the increase in quality because the difference between water and steam is minor in this pressure region. The results provide some instructive advices to improve the design and operation safety of once-through boiler. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据