4.7 Article

Exergy recovery in regasification facilities - Cold utilization: A modular unit

期刊

APPLIED THERMAL ENGINEERING
卷 29, 期 17-18, 页码 3595-3608

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2009.06.016

关键词

LNG regasification - cold utilization; Carbon dioxide as secondary refrigerant; Exergy and economic analysis; Safety of LNG regasifiers

向作者/读者索取更多资源

The paper deals with the problem of cold recovery for direct utilization both in the site of regasification facility and far from it. A modular LNG regasification unit is proposed having the regasification capacity of 2 billion standard cubic meters/year of gas. The modular plant is based on use of a power cycle working with ethane or ethylene which allows operation of cold energy transfer, contained in LNG to be regasified, in a range of temperatures suitable for multipurpose use of cold, reducing regasification process irreversibility. Some electric energy is produced by the power cycle, but the own mission of modular unit proposed is addressed to deliver cold suitable for industrial and commercial use in the proper temperature range. The option considers. also, the use of carbon dioxide as a secondary fluid for transfer of cold from regasification site to far end users. This option seems very attractive due to expected wide future exploitation of LNG regasification in the world. Results of a detailed thermodynamic and economic analysis demonstrate the suitability of the proposal. (C) 2009 Elsevier Ltd. Ail rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据