Comparison of ultrafiltration and solid phase extraction for the separation of free and protein-bound serum copper for the Wilson's disease diagnosis

期刊

CLINICA CHIMICA ACTA
卷 345, 期 1-2, 页码 113-121

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.cccn.2004.03.001

关键词

copper; GF AAS; Wilson disease; protein adsorption; SPE; polyethylene

向作者/读者索取更多资源

Background: The determination of the ratio free/protein-bound serum copper along with urinary copper can be used as a preliminary test for the Wilson's Disease diagnosis. In this work, the determination of these copper fractions in serum samples was carried out in two different ways; after separation of the copper bound to proteins from the free fraction by a column for protein adsorption and by ultrafiltration. As proteins can be adsorbed onto plastic polymeric surfaces, polyethylene (PE) with different molecular weights in powder form was investigated for protein adsorption. A small column was adapted in a flow system to carry out a solid-phase extraction (SPE) on-line. Preliminary experiments defined conditions for protein retention and elution and column saturation. Good performance was achieved using Mg(NO3)(2) solution as carrier and methanol as eluent. The presence of proteins in both fraction (column effluent and eluate) was checked by the Coomassie Brilliant Blue test. Copper was measured by graphite furnace atomic absorption spectrometry. The measurement in the column effluent furnished the free-fraction of copper while the copper measured in the eluate the bound-fraction. The method was compared with ultrafiltration (20 kDa), measuring the free-copper in the ultrafiltrate. For the determination of protein-bound copper, the copper found in the ultrafitrate was discounted from the total copper measured in the sample. Results: Serum samples of 10 individuals were analyzed by both methods with good agreement of the results. The regression plots, obtained by analysing the samples by both methods, presented r(2) and slope of 0.97 and 0.96 for free copper and 1.00 and 1.00 for bound copper, respectively. Protein-bound copper (PB) concentrations ranged from 74 to 2074 mug/l and free-copper (F) from 22 to 54 mug/l. The ratio F/PB, calculated from SPE data, was 29.7% for one individual, with Wilson Disease well-characterized, and ranged from 1.2% to 5.2% for the others. Conclusion: The SPE method performed well in terms of accuracy and precision, and showed good agreement with the UF. Advantages of SPE are small sample volume (50 mul), separation carried out in 10 min, and the use of the same column for several analyses. (C) 2004 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据