APPLIED SPECTROSCOPY
卷 64, 期 3, 页码 245-254出版社
SOC APPLIED SPECTROSCOPY
DOI: 10.1366/000370210790918300
关键词
Light scattering; Path length distribution; Near-infrared spectroscopy; Nonlinearity; Multivariate calibration; Partial least squares; PLS; Principal component regression; PCR
资金
- Natural Sciences and Engineering Research Council of Canada (NSERC)
- Walter C. Sumner Foundation
- Dalhousie University
Near-infrared (NIR) spectroscopy has been used for noninvasive measurements of solid and liquid samples, through highly scattering media such as colloids, food, and tissue. It has seen many applications in agriculture, medicine, and petroleum industries, mainly due to the minimal sample preparation that is required. This minimal sample preparation does come at a cost to the analyst, since the high signal-to-noise ratio of a typical NIR instrument can be riddled with effects stemming from heterogeneity and the scattering of light. This work proposes a novel preprocessing method, the path length distribution correction (PDC) method, to correct spectral nonlinearities in samples of highly scattering media. These nonlinearities stem from the distribution of path lengths of the incident light, which are a result of the scattering of light in the sample. Recent developments in time-of-flight (TOE) spectroscopy have allowed for the acquisition of the distribution of times that photons travel within a sample simultaneous with the collection of the NIR spectrum. The TOE distribution is used to estimate a path length distribution within a sample, which is then used to fix the measurement spectra, giving each spectrum an apparent path length of unity. The PDC-corrected spectra can then be used with traditional multivariate calibration methods such as principal component regression (PCR) and partial least squares (PLS). Another discussion looks at the viability of using a lognormal distribution as a simple approximation of the TOF distribution. This would be very useful in circumstances in which experimental TOE distributions are not collected. PDC is shown to significantly improve prediction errors in experimental data sets, while diagnostic plots indicate that the corrected spectra do appear to have a path length of unity, thus alleviating effects of the distribution of path lengths.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据