4.7 Article

Removal of pollutants from indoor air using zeolite membranes

期刊

JOURNAL OF MEMBRANE SCIENCE
卷 240, 期 1-2, 页码 159-166

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.memsci.2004.05.004

关键词

zeolite membrane; indoor air pollution; VOC separation; low concentration

向作者/读者索取更多资源

MFI-type zeolite membranes prepared by liquid phase hydrothermal synthesis on tubular commercial supports were used to remove model pollutants n-hexane, formaldehyde and benzene present at very low concentration levels (2-230 ppmv) in indoor air. The influence of several operating parameters was studied both in batch and continuous separation experiments. Depending on the operation conditions, permeation C fluxes of the organic compound up to 3300, 130 and 30 mg/m(2)h) and organic/air separation factors of 250, 6.3 and 38 were achieved for n-hexane, formaldehyde and benzene, respectively. (C) 2004 Elsevier B.V. All rights reserved.

作者