4.4 Article Proceedings Paper

Progress in the use of gadolinium for NCT

期刊

APPLIED RADIATION AND ISOTOPES
卷 67, 期 7-8, 页码 S157-S160

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.apradiso.2009.03.109

关键词

GdNCT; Gadolinium; Nanodosimetry; Auger electron; Treatment planning system

向作者/读者索取更多资源

The evaluation of possible improvement in the use of Gd in cancer therapy, in reference to gadolinium in cancer therapy (GdNCT), has been analysed. At first the problem of the gadolinium compounds toxicity was reviewed identifying the Motexafin Gadolinium as the best. Afterwards, the spectrum of IC and Auger electrons was calculated using a special method. Afterwards, this electron source has been used as input of the PENELOPE code and the energy deposit in DNA was well defined. Taking into account that the electron yield and energy distribution are related to the neutron beam spectrum and intensity, the shaping assembly architecture was optimised through computational investigations. Finally the study of GdNCT was performed from two different points of view: macrodosimetry using MCNPX, with calculation of absorbed doses both in tumour and healthy tissues, and microdosimetry using PENELOPE, with the determination of electron RBE through the energy deposit. The equivalent doses were determined combining these two kinds of data, introducing specific figures of merit to be used in treatment planning system (TPS). According to these results, the GdNCT appears to be a fairly possible tumour therapy. (C) 2009 Elsevier Ltd. All rights reserved.