3.9 Article

Arrhenius average temperature: The effective temperature for non-fatigue wearout and long term reliability in variable thermal conditions and climates

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TCAPT.2004.831834

关键词

Arrhenius average temperature; thermal acceleration factors; thermal fatigue

向作者/读者索取更多资源

This paper, presents a method of assessing the effective temperature essential for predicting the temperature acceleration of the wearout mechanisms (other than thermal fatigue) of electronic equipment., This is particularly important for equipment experiencing variable thermal conditions. The approach, based on weighting of thermal acceleration factors, leads to the Arrhenius average temperature T-eff given by (4). T-eff is related to wearout processes and allows one to compare predictions from the thermal design to results of accelerated testing. It has no relation to the maximum component temperature which influences functionality. The method is applicable to outside plant telecommunication equipment as well as in the automotive and aerospace industries. The effect of climate and design constraints on T-eff are discussed.