4.6 Article

The vague of ultrasound in the prediction of successful induction of labor

期刊

ULTRASOUND IN OBSTETRICS & GYNECOLOGY
卷 24, 期 5, 页码 538-549

出版社

WILEY
DOI: 10.1002/uog.1100

关键词

body mass index; cervical length; gestational age; induction of labor; maternal age; occipital position; parity; posterior cervical angle; ultrasound

向作者/读者索取更多资源

Objectives To examine the value of pre-induction sonographic assessment of cervical length, posterior cervical angle and occipital position in the prediction of the induction-to-delivery interval within 24 h, the likelihood of vaginal delivery within 24 h, the likelihood of Cesarean section and to compare sonographic assessment with the Bishop score. Methods In 604 singleton pregnancies, induction of labor was carried out at 35-42 weeks of gestation. Immediately before induction, transvaginal sonography was performed for measurement of cervical length and posterior cervical angle and a transabdominal scan was carried out to determine the position of the fetal occiput. The value of occipital position, posterior cervical angle, cervical length, parity, gestational age, maternal age, and body mass index (BMI) on the induction-to-delivery interval within 24 h, the likelihood of vaginal delivery within 24 h and the likelihood of Cesarean section were investigated by Cox proportional hazard model or logistic regression analysis. Results Vaginal delivery occurred in 484 (80.1%) women and this was within 24 h of induction in 388 (64.2%). Cesarean section was performed in 120 (19.9%). Occiput-anterior (OA) and transverse (OT) positions were analyzed as one group as the odds ratios (OR) and the HR were similar and different from occiput-posterior (OP), which was analyzed as another group. Prediction of the induction-to-delivery interval was provided by the occipital position, pre-induction cervical length, parity and posterior cervical angle. Prediction of the likelihood of vaginal delivery within 24 h was provided by the occipital position, cervical length, posterior cervical angle and BMI. Prediction of the likelihood of Cesarean section was provided by the occipital position, cervical length, parity, maternal age and BMI. In the prediction of vaginal delivery within 24 h, for a specificity of 75%, the sensitivity for ultrasound findings was 89% and for the Bishop score it was 65%. The respective sensitivities for Cesarean section were 78% and 53%. Conclusion In women undergoing induction of labor, significant independent Prediction of the induction-to-delivery interval within 24 h, the likelihood of vaginal delivery within 24 h and the likelihood of Cesarean section are provided by pre-induction cervical length, occipital position, posterior cervical angle and maternal characteristics. Sonographic parameters were superior to the Bishop score in the prediction of the outcome of induction. Copyright (C) 2004 ISUOG. Published by John Wiley Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据