期刊
ARCHIVES OF ORAL BIOLOGY
卷 49, 期 11, 页码 863-869出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.archoralbio.2004.05.002
关键词
human saliva; anionic analysis; ion chromatography
Objective: To survey concentrations and time-variability of the major anions of human saliva using ion chromatography (IC). Materials and methods: Resting saliva samples after overnight fasting, obtained under standardized conditions in time-series for 10 subjects, were analysed for chloride, phosphate, nitrate, sulphate, thiocyanate, acetate and lactate. A second group of five subjects provided mixed sativa as before, and in addition a sample of parotid saliva collected immediately afterwards using a Lashley cup. Analysis was by ion chromatography (DX-100, Dionex) using 1.7 mM NaHCO3 + 1.8 mM Na2CO3 + 100 mg/L p-cyanophenot (2 mL/min) and 1.6 mM perfluorobutyric acid + 0.3 mM, sodium hydroxide (0.3 mL/min) as eluents for inorganic and organic anions, respectively. Results: The time-series data showed great natural. variability. Analysis of the correlations showed that the concentration of nitrate was uncoupled from those of the other anions. Lactate was not detected. Parotid saliva showed marked differences from mixed saliva, most notably the absence of acetate and the presence in two instances of lactate. Bromide, nitrite and citrate were not detected. Conclusions: Acetate is a major component of the oral chemical, environment. Simultaneous analyses permit the investigation of the relationships between component concentrations that otherwise might have been difficult to study. (C) 2004 Elsevier Ltd. All rights reserved.