4.8 Article

Detection of enteric viruses, Giardia and Cryptosporidium in two different types of drinking waterle treatment facilities

期刊

WATER RESEARCH
卷 38, 期 18, 页码 3931-3939

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2004.06.014

关键词

drinking water; enteroviruses; Giardia; Cryptosporidium; RT-PCR

向作者/读者索取更多资源

In this study, two types of drinking water treatment facilities (two conventional drinking water treatment plants (DWTPs) and two compact units (Cus)) were compared referring to their production capacity. Water samples were collected from three main points: (a) different water treatment steps (b) washings of sand filters and (c) distribution system at different distances from the water treatment plants. Both viruses and protozoa were concentrated from each water sample by adsorption and accumulation on the same nitrocellulose membrane filters (0.45 mum pore size). Enteroviruses were detected by plaque infectivity assay in BGM cells and HAV, HEV and Norovirus were detected by RT-PCR. Giardia and Cryptosporidium were detected by conventional staining methods and PCR. The results revealed that enterovirus load at the intake ranged between 10-15PFU/L for the two compact units and between 4.5 and 75 PFU/L for the two conventional DWTPs. The virus load in distribution system of the first type DWTPs at I km from the plant was the same as that of the intake. Viruses in the other type of treatment plants CUs at 1, 5 and 7 km, were much reduced. Investigation of raw water sediments of the two DWTPs showed enterovirus counts between 12 and 17.5 PFU/L. Virus count was reduced in sand of filters after washing. Giardia cysts were equally detected by microscopy and PCR in only intake samples of EL-Hawamdia CU (33.3%) and Meet Fares DWTP (50%). Cryptosporidium oocysts were equally detected by microscopy and PCR in intake samples of Abo EL-Nomros CU (100%), EL-Hawamdia CU (66.7%) and Fowa DWTP (50%). At Meet Fares DWTP three positive intake samples for Cryptosporidium were detected by PCR, compared with only two positive samples by microscopy. Giardia cysts and Cryptosporidium oocysts were detected in raw water sediment and sand of filters before washing. Only one sample from Meet Fares DWTP sand of filters after washing was positive for both Giardia and Cryptosporidium. It can be concluded that the poor microbial quality of the water may be due to improper operational skills and management of the various water treatment plants (especially at the two high capacity treatment plants). (C) 2004 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据