4.6 Article

Real-time monitoring of high-temperature corrosion in stainless steels by open-path laser-induced plasma spectrometry

期刊

APPLIED SPECTROSCOPY
卷 58, 期 11, 页码 1347-1352

出版社

SAGE PUBLICATIONS INC
DOI: 10.1366/0003702042475538

关键词

laser-induced plasma spectrometry; LIPS; remote analysis; stainless steel; real-time analysis; laser plasmas

向作者/读者索取更多资源

Open-path laser-induced plasma spectrometry (OP-LIPS) represents an appealing alternative for the real-time monitoring of high-temperature processes due to its inherent non-invasive and remote capabilities. In this work, stainless steel samples have been analyzed at 10 meters from the laser source. The effect of the high-temperature conditions to the protective anti-corrosion layer have been analyzed, as well as additional factors such as the type of steel and the exposure time. The number of pulses required to ablate the alteration layer has been found to follow a linear relationship with the square root of the exposure time, in excellent agreement with the off-line thermogravimetric measurements described in the literature.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据