4.7 Article

Process intensification in the textile industry: the role of membrane technology

期刊

JOURNAL OF ENVIRONMENTAL MANAGEMENT
卷 73, 期 3, 页码 267-274

出版社

ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jenvman.2004.07.007

关键词

process intensification; textile industry; finishing baths; dye baths; water reuse; nanofiltration; microfiltration; membrane distillation; membrane crystallizer

向作者/读者索取更多资源

Process intensification is a concept that was recently introduced in the chemical industry for the purpose of reducing environmental emissions, energy consumption and materials consumption. The principle of process intensification can be used in related industries as well; textile finishing is an exemplary activity where it may have a significant long-term added value. Membrane technology can be a key factor in the recycling and reuse of energy, water and chemicals. In this paper, an integral approach for treatment of aqueous process streams in the textile finishing industry is proposed. The proposed process includes microfiltration pretreatment of used finishing baths, followed by a dual nanofiltration (NF) unit. These can be operated at elevated temperatures so that no further energy is needed for preheating of recycle streams. In the proposed treatment scheme, the first of the NF units uses a loose nanofiltration membrane that retains most of the organic fraction but not the dissolved salts. The second unit uses a tight nanofiltration membrane, which produces a permeate fraction that can be directly reused, and a concentrated brine that is fed to a membrane crystallizer. In this unit, salts are recovered and recycled for use in new dye baths. The concentrate stream from the first NF unit is fed to a membrane distillation unit, where the high temperature is advantageously used for further concentration. The remaining fraction is not reusable, given the fact that most dyes are hydrolyzed after exhaustion of the bath, but has a significant energetic value, which can be utilized for compensation of energy losses and preheating of suppletion water, by using an incineration process with energy recovery. The concept was not tested experimentally, but a simulation for a 500 m(3)/d production unit shows that it is feasible, although modifications may be necessary depending on the nature of the finishing baths. Furthermore, the membrane choice in the first NF unit is a critical aspect. (C) 2004 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据