期刊
APPLIED ERGONOMICS
卷 35, 期 6, 页码 603-614出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.apergo.2004.06.007
关键词
observation method; patient handling; transfer technique
The aim of the present study was to evaluate the reliability and validity of an observation instrument for patient transfer. The instrument, which consisted of 23 items, was evaluated on five different patient transfer tasks. A weighted score was included to evaluate the performed transfer technique. Four observers were selected for the assessment of instrument intra- and inter-observer reliability. Instrument validity was evaluated by testing whether the instrument could detect a difference between use of a self-chosen and a recommended transfer technique. Furthermore, calculated compression values at L4-L5 were compared with the weighted score for the different transfer technique situations. Eleven items were reliable. Nine items deserve further attention and three items were not reliable. The weighted score was significantly higher for the recommended transfer technique situations (P < 0.01) and an association between the weighted score and the calculated compression values was observed (r = -0.589). (C) 2004 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐