4.7 Article

Regression of electrocardiographic left ventricular hypertrophy during antihypertensive treatment and the prediction of major cardiovascular events

期刊

JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION
卷 292, 期 19, 页码 2343-2349

出版社

AMER MEDICAL ASSOC
DOI: 10.1001/jama.292.19.2343

关键词

-

向作者/读者索取更多资源

Context Electrocardiographic left ventricular hypertrophy (LVH) is a strong predictor of cardiovascular (CV) morbidity and mortality. However, the predictive value of changes in the magnitude of electrocardiographic LVH criteria during antihypertensive therapy remains unclear. Objective To test the hypothesis that lesser severity of electrocardiographic LVH during anti hypertensive treatment is associated with decreased CV morbidity and mortality; independent of blood pressure levels and reduction and treatment modality. Design, Setting, and Participants Double-blind, randomized, parallel-group study conducted in 1995-2001 among 9193 men and women with hypertension aged 55 through 80 years (mean, 67 years), with electrocardiographic LVH by Cornell voltage-duration product or Sokolow-Lyon voltage criteria and enrolled in the Losartan Intervention For Endpoint Reduction in Hypertension (LIFE) study. Interventions Losartan- or atenolol-based treatment regimens, with follow-up assessments for at least 4 (mean, 4.8 [SD, 0.9]) years. Main Outcome Measure Composite end point of CV death, myocardial infarction (MI), or stroke in relation to severity of electrocardiographic LVH determined at baseline and on subsequent electrocardiograms obtained at 1 or more annual revisits. Results Cardiovascular death, nonfatal MI, or stroke occurred in 1096 patients (11.9%). In Cox regression models controlling for treatment type, baseline Framingham risk score, baseline and in-treatment blood pressure, and severity of baseline electrocardiographic LVH by Cornell product and Sokolow-Lyon voltage, less-severe in-treatment LVH by Cornell product and Sokolow-Lyon voltage were associated with 14% and 17% lower rates, respectively, of the composite CV end point (adjusted hazard ratio [HR], 0.86; 95% confidence interval [CI], 0.82-0.90; P<.001 for every 1050-mm x ms [1-SD] decrease in Cornell product; and HR, 0.83; 95% CI, 0.78-0.88; P<.001 for every 10.5-mm [1-SD] decrease in Sokolow-Lyon voltage). In parallel analyses, lower Cornell product and Sokolow-Lyon voltage were each independently associated with lower risks of CV mortality (HR, 0.78; 95% CI 0.73-0.83; P<.001; and HR, 0.80; 95% CI 0.73-0.87; P<.001, respectively), MI (HR 0.90; 95% CI, 0.82-0.98; P=.01; and HR, 0.90; 95% CI, 0.81-1.00; P=.04), and stroke (HR, 0.90; 95% CI, 0.840.96; P=.002; and HR, 0.81; 95% CI, 0.75-0.89; P<.001). Conclusions Less-severe electrocardiographic LVH by Cornell product and Sokolow- Lyon voltage criteria during antihypertensive therapy is associated with lower likelihoods of CV morbidity and mortality independent of blood pressure lowering and treatment modality in persons with essential hypertension. Antihypertensive therapy targeted at regression or prevention of electrocardiographic LVH may improve prognosis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据