4.5 Article

The SiOG-based single-crystalline silicon (SCS) RF MEMS switch with uniform characteristics

期刊

JOURNAL OF MICROELECTROMECHANICAL SYSTEMS
卷 13, 期 6, 页码 1036-1042

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JMEMS.2004.838365

关键词

performance uniformity; RF MEMS; single-crystalline silicon (SCS); SiOG process

向作者/读者索取更多资源

This paper details single-crystalline silicon (SCS) direct contact radio frequency microelectromechanical systems (RF MEMS) switch designed and fabricated using an SiOG (silicon-on-glass) substrate, so as to obtain higher fabrication and performance uniformity compared with a conventional metal switch. The mechanical and electrical performances of the fabricated silicon switch have been tested. In comparison with a conventional metallic MEMS switch, we can obtain higher productivity and uniformity by using SCS, because it has very low stresses and superior thermal characteristics as a structural material of the switch. Also, by using the SiOG substrate instead of an SOI substrate, fabrication cost can be significantly reduced. The proposed switch is fabricated on a coplanar waveguide (CPW) and actuated by electrostatic force. The designed chip size is 1.05 mm x 0.72 mm. Measured pull-in voltage and actuation voltage were 19 V and 26 V, respectively. Eighteen identical switches taken randomly throughout the wafer showed average and standard deviation of the measured pull-in voltage of 19.1 and 1.5 V, respectively. The RF characteristics of the fabricated switch from de to 30 GHz have been measured. The isolation and insertion loss measured on the four identical samples were -38 to -39 dB and -0.18 to -0.2 dB at 2 GHz, respectively. Forming damping holes on the upper electrode leads to a relatively fast switching speed. Measured ON and OFF time were 25 and 13 mus, respectively. In the switch OFF state, self-actuation does not happen up to the input power of 34 dBm. The measured holding power of the fabricated switch was 31 dBm. Stiction problem was not observed after 10(8) cycles of repeated actuation, but the contact resistance varied about 0.5-1 Omega from the initial value.hbox.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据