4.6 Article

Determination of nitroaromatic and nitramine explosives from a PTFE wipe using thermal desorption-gas chromatography with electron-capture detection

期刊

JOURNAL OF CHROMATOGRAPHY A
卷 1062, 期 1, 页码 125-131

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2004.11.028

关键词

explosives; thermal desorption; GC-ECD; dry wipe; dual column; dual ECD

向作者/读者索取更多资源

A method for the detection of nitroaromatic and nitramine explosives from a PTFE wipe has been developed using thermal desorption and gas chromatography with electron-capture detection (TD-GC-ECD). For method development a standard mixture containing eight nitroaromatic and two nitramine (HMX and RDX) explosive compounds was spiked onto a PTFE wipe. Explosives were desorbed from the wipe in a commercial thermal desorption system and trapped onto a cooled injection system, which was incorporated into the injection port of the GC. A dual column, dual ECD configuration was adopted to enable simultaneous confirmation analysis of the explosives desorbed. For the desorption of 50ng of each explosive, desorption efficiencies ranged between 80.0 and 117%, for both columns. Linearity over the range 2.5-50 ng was demonstrated for each explosive on both columns with r(2) values ranging from 0.979 to 0.991 and limits of detection less than 4 ng. Desorption of HMX from a PTFE wipe has also been demonstrated for the first time, albeit at relatively high loadings (100 ng). (C) 2004 Elsevier B.V. All rights reserved.