The accuracy of the manufacturer's fall-rate equation for the T-5 Model of expendable bathythermograph (XBT) has been investigated based on about 300 collocated pairs of XBT-CTD (Conductivity-Temperature-Depth profiler) measurements in various climatological regions. We found that the equation systematically overestimates depth by about 5% for the T-5 produced by Tsurumi Seiki, Co. Ltd. (TSK), but almost no bias is associated with the T-5 produced by Sippican, Inc., in USA. The cause of this difference is not clear, because the two manufacturers'T-5 probes are reported to have identical shape and weight in water. We propose a new fall-rate equation for the TSK T-5: z(t) = 6.54071t - 0.0018961t(2), where z(t) is depth in meters at time, t, in seconds.