Automatic generation of a plan optimization volume for tangential field breast cancer radiation therapy

期刊

STRAHLENTHERAPIE UND ONKOLOGIE
卷 181, 期 2, 页码 82-88

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00066-005-1310-1

关键词

breast cancer; automated generation; plan optimization

向作者/读者索取更多资源

Background and Purpose: Dose homogeneity is one of the objectives during computer planning of postoperative radiotherapy of the conserved breast. For three-dimensional (3-D) optimization of the dose distribution using serial CT scan images, suitable volumes have to be delineated. The purpose of this study was to develop a computer-generated delineation of a plan optimization volume (POV) and an irradiated volume (IV) and to automate their use in a fast dose homogeneity optimization engine. Patients and Methods: Simulation was performed according to our standard procedure which involves the positioning of a lead collar around the palpable breast to facilitate the definition of gantry angle, collimator angle and field aperture for tangential wedged photon beams. In a change to the standard procedure an anterolateral radiograph was taken with its axis orthogonal to the central plane of the two tangential half-beams. Images from a serial CT scan were acquired in treatment position, and the geometric data of the three simulated beams were used by a computer program to generate the POV and IV. For each patient, weights of wedged and unwedged beams were optimized by either human heuristics using only the central slice (2-D), the whole set of CT slices (3-D), or by a computer algorithm using the POV, IV and Lung volume with constrained matrix inversion (CMI) as optimization method. The resulting dose distributions were compared. Results: The total planning procedure took, on average, 44 min of which < 7 min were needed for human interactions, compared to about 52 min for the standard planning at Ghent University Hospital, Belgium. The simulation time is increased by 2-3 min. The method provides 3-D information of the dose distribution. Dose homogeneity and minimum dose inside the POV and maximum dose inside the IV were not significantly different for the three optimization techniques. Conclusion: This automated planning method is capable of replacing the contouring of the clinical target volume as well as the trial-and-error procedure of assigning weights of wedged and unwedged beams by an experienced planner.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据