4.4 Article Proceedings Paper

The 3rd international intercomparison on EPR tooth dosimetry: Part 1, general analysis

期刊

APPLIED RADIATION AND ISOTOPES
卷 62, 期 2, 页码 163-171

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.apradiso.2004.08.027

关键词

EPR; tooth enamel; gamma irradiation; retrospective dosimetry; intercomparison

向作者/读者索取更多资源

The, objective of the 3rd International Intercomparison on Electron Paramagnetic Resonance (EPR) Tooth Dosimetry was the evaluation of laboratories performing tooth enamel dosimetry below 300 mGy. Participants had to reconstruct the absorbed dose in tooth enamel from 1 1 molars, which were cut into two halves. One half of each tooth was irradiated in a Co-60 beam to doses in the ranges of 30-100 mGy (5 samples), 100-300mGy (5 samples), and 300-900 mGy (1 sample). Fourteen international laboratories participated in this intercomparison programme. A first analysis of the results and an overview of the essential features of methods applied in different laboratories are presented. The relative standard deviation of results of all methods was better than 27% for applied doses in the range of 79-704 mGy. In the analysis of the unirradiated tooth halves 8% of the samples were identified as outliers with additional absorbed dose above background dose. (C) 2004 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据