期刊
KOREAN JOURNAL OF CHEMICAL ENGINEERING
卷 22, 期 2, 页码 264-267出版社
KOREAN INSTITUTE CHEMICAL ENGINEERS
DOI: 10.1007/BF02701495
关键词
adsorption isotherm; molecular imprinted polymer; Ibuprofen; HPLC
A molecular imprinted polymer (MIP) using (+)-(S)-2-(4-isobutylphenyl) propionic acid ((+)-(S)-ibuprofen) as the template and 4-vinylpyridine (4-VPY) as the functional monomer was prepared. Chloroform and acetonitrile were used as the porogen with ethylene glycol dimethacrylate (EGDMA) as the crosslinker and 2,2'-azobis(isobutyronitrile) (AIBN) as the initiator. Comparison of ibuprofen adsorption isotherm on molecular imprinted and blank polymers was made by the static method. The adsorption equilibrium data were correlated into the Freundlich, Langmuir, Sips (Langmuir-Freundlich) and Radke-Prausnitz isotherm models, respectively. By a nonlinear regression analysis, the experimental parameters in the equilibrium isotherms were estimated and compared. The calculated data is well fitted with the experimented data. Through the analysis, the ibuprofen imprinted polymer showed higher adsorption ability than blank polymer.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐