4.6 Article

Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation

期刊

JACC-CARDIOVASCULAR INTERVENTIONS
卷 8, 期 9, 页码 1218-1228

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2015.05.010

关键词

atrioventricular block; CT; implantation depth; membranous septum; permanent pacemaker; TAVI

向作者/读者索取更多资源

OBJECTIVES This study sought to examine whether imaging of the atrioventricular (AV) membranous septum (MS) by computed tomography (CT) can be used to identify patient-specific anatomic risk of high-degree AV block and permanent pacemaker (PPM) implantation before transcatheter aortic valve implantation (TAVI) with self-expandable valves. BACKGROUND MS length represents an anatomic surrogate of the distance between the aortic annulus and the bundle of His and may therefore be inversely related to the risk of conduction system abnormalities after TAVI. METHODS Seventy-three consecutive patients with severe aortic stenosis underwent contrast-enhanced CT before TAVI. The aortic annulus, aortic valve, and AV junction were assessed, and MS length was measured in the coronal view. RESULTS In 13 patients (18%), high-degree AV block developed, and 21 patients (29%) received a PPM. Multivariable logistic regression analysis revealed MS length as the most powerful pre-procedural independent predictor of high-degree AV block (odds ratio [OR]: 1.35, 95% confidence interval [CI]: 1.1 to 1.7, p = 0.01) and PPM implantation (OR: 1.43, 95% CI: 1.1 to 1.8, p = 0.002). When taking into account pre- and post-procedural parameters, the difference between MS length and implantation depth emerged as the most powerful independent predictor of high-degree AV block (OR: 1.4, 95% CI: 1.2 to 1.7, p < 0.001), whereas the difference between MS length and implantation depth and calcification in the basal septum were the most powerful independent predictors of PPM implantation (OR: 1.39, 95% CI: 1.2 to 1.7, p < 0.001 and OR: 4.9, 95% CI: 1.2 to 20.5, p = 0.03; respectively). CONCLUSIONS Short MS, insufficient difference between MS length and implantation depth, and the presence of calcification in the basal septum, factors that may all facilitate mechanical compression of the conduction tissue by the implanted valve, predict conduction abnormalities after TAVI with self-expandable valves. CT assessment of membranous septal anatomy provides unique pre-procedural information about the patient-specific propensity for the risk of AV block. (C) 2015 by the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据