4.6 Article

A Randomized Evaluation of the SAPIEN XT Transcatheter Heart Valve System in Patients With Aortic Stenosis Who Are Not Candidates for Surgery

期刊

JACC-CARDIOVASCULAR INTERVENTIONS
卷 8, 期 14, 页码 1797-1806

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcin.2015.08.017

关键词

aortic stenosis; inoperable; SAPIEN XT; TAVR; transcatheter aortic valve replacement

资金

  1. Edwards Lifesciences
  2. National Institutes of Health [5T32HL007854-19]
  3. Abiomed
  4. St. Jude Medical
  5. National Heart, Lung, and Blood Institute [HL67025]
  6. Medtronic
  7. Abbott Vascular
  8. DirectFlow
  9. Boston Scientific
  10. Gore
  11. Siemens
  12. Cardiokinetix
  13. Mitraspan

向作者/读者索取更多资源

OBJECTIVES The purpose of this study was to determine the safety and effectiveness of the SAPIEN XT versus SAPIEN systems (Edwards Lifesciences, Irvine, California) in patients with symptomatic, severe aortic stenosis (AS) who were not candidates for surgery. BACKGROUND Transcatheter aortic valve replacement (TAVR) has become the standard of care for inoperable patients with severe, symptomatic AS. In the PARTNER (Placement of Aortic Transcatheter Valves) IB trial, a reduction in all-cause mortality was observed in patients undergoing TAVR with the balloon-expandable SAPIEN transcatheter heart valve compared with standard therapy, but the SAPIEN valve was associated with adverse periprocedural complications, including vascular complications, major bleeding, and paravalvular regurgitation. The newer, low-profile SAPIEN XT system was developed to reduce these adverse events. METHODS A total of 560 patients were enrolled at 28 sites in the United States from April 2011 to February 2012. Patients were randomized to receive the SAPIEN or SAPIEN XT systems. The primary endpoint was a nonhierarchical composite of all-cause mortality, major stroke, and rehospitalization at 1 year in the intention-to-treat population, assessed by noninferiority testing. Pre-specified secondary endpoints included cardiovascular death, New York Heart Association functional class, myocardial infarction, stroke, acute kidney injury, vascular complications, bleeding, 6-min walk distance, and valve performance (by echocardiography). RESULTS Both overall and major vascular complications were higher at 30 days in patients undergoing TAVR with SAPIEN compared with SAPIEN XT (overall: 22.1% vs. 15.5%; p = 0.04; major: 15.2% vs. 9.5%; p = 0.04). Bleeding requiring blood transfusions was also more frequent with SAPIEN compared with SAPIEN XT (10.6% vs. 5.3%; p = 0.02). At 1-year follow-up, the nonhierarchical composite of all-cause mortality, major stroke, or rehospitalization was similar (37.7% SAPIEN vs. 37.2% SAPIEN XT; noninferiority p value < 0.002); no differences in the other major pre-specified endpoints were found. CONCLUSIONS In inoperable patients with severe, symptomatic AS, the lower-profile SAPIEN XT is noninferior to SAPIEN with fewer vascular complications and a lesser need for blood transfusion. (C) 2015 by the American College of Cardiology Foundation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据