4.6 Article

Multi-zone modeling of probable SARS virus transmission by airflow between flats in Block E, Amoy Gardens

期刊

INDOOR AIR
卷 15, 期 2, 页码 96-111

出版社

WILEY
DOI: 10.1111/j.1600-0668.2004.00318.x

关键词

severe acute respiratory syndrome; infection control; infiltration; multi-zone modeling; residential buildings; natural ventilation

向作者/读者索取更多资源

More than 300 residents of a private high-rise housing estate were infected with severe acute respiratory syndrome within a short period during the 2003 epidemic in Hong Kong. The outbreak occurred after the identified index patient visited a flat on a middle floor in Block E of the Amoy Gardens estate on two nights. Approximately 45% of the subsequently infected people resided in Block E, while the other 55% of infected cases mainly resided in six other blocks close to Block E. The distribution of the infected flats in Block E conformed to a non-uniform spatial pattern. Probable environmental causes for airborne transmission associated with the air movements between flats in Block E are identified. The well-established multi-zone airflow modeling method was used to analyze the virus-laden bio-aerosol dispersion between flats through door and window leakage areas in Block E under six different scenarios. The distribution of infection risk in Block E matched with the virus concentrations in flats predicted with the use of multi-zone modeling. Our study shows the importance of ventilation design in high-rise residential apartments.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据