期刊
JOURNAL OF CHROMATOGRAPHY A
卷 1070, 期 1-2, 页码 137-145出版社
ELSEVIER
DOI: 10.1016/j.chroma.2005.02.055
关键词
airborne molecular contaminants; phthalate esters; GC-MS; cleanroom; wafer contamination; surface desorption
This study established an analytical method for the trace analyses of two phthalate esters, including diethyl phthalate (DEP) and di-n-butyl phthalate (DBP), known as the major constituents of cleanroom micro-contamination detrimental to the reliability of semiconductor devices. Using thermal desorption coupled with a GC-MS system, standard tubes were prepared by delivering liquid standards pre-vaporized by a quasi-vaporizer into Tenax GR tubes for calibration. This method was capable of achieving detection limits of 0.05 mu g m(-3) for 0.1 m(3) air samples and 0.03 ng cm(-2) for 150-mm wafer surface density. Actual samples collected from a semiconductor cleanroom showed that the concentration of DBP in a polypropylene wafer box (0.45 mu g m(-3)) was nearly four times higher than that in the cleanroom environment (0.12 mu g m(-3)). The surface contamination of DBP was 0.67 ng cm(-2) for a wafer stored in the wafer box for 24 h. Furthermore, among the three types of heat-resistant O-ring materials tested, Kalrez((R)) was found to be particularly suitable for high-temperature processes in semiconductor cleanrooms due to their low emissions of organic vapors. This analytical procedure should serve as an effective monitoring method for the organic micro-contamination in cleanroom environments. (c) 2005 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐