期刊
JOURNAL OF PERIODONTOLOGY
卷 76, 期 5, 页码 791-802出版社
WILEY
DOI: 10.1902/jop.2005.76.5.791
关键词
aggressive periodontitis; bone loss/prevention and control; bone remodeling; chronic periodontitis; comparative retrospective study; comparison studies; crestal bone changes; dental implants; follow-up studies; human studies; long-term data; non-submerged implants; oral hygiene; periodontitis; radiography
Background: Experimental studies demonstrated that peri-implant crestal hard and soft tissues are significantly influenced in their apico-coronal position by the rough/smooth implant border as well as the microgap/interface between implant and abutment/restoration. The aim of this study was to evaluate radiographically the crestal bone level changes around two types of implants, one with a 2.8 mm smooth machined coronal length and the other with 1.8 mm collar. Methods: In 68 patients, a total of 201 non-submerged titanium implants (101 with a 1.8 mm, 100 with a 2.8 mm long smooth coronal collar) were placed with their rough/smooth implant border at the bone crest level. From the day of surgery up until 3 years after implant placement crestal bone levels were analyzed digitally using standardized radiographs. Results: Bone remodeling was most pronounced during the unloaded, initial healing phase and did not significantly differ between the two types of implants over the entire observation period (P > 0.20). Crestal bone loss for implants placed in patients with poor oral hygiene was significantly higher than in patients with adequate or good plaque control (P < 0.005). Furthermore, a tendency for additional crestal bone loss was detected in the group of patients who had been diagnosed with aggressive periodontitis prior to implant placement (P=0.058). In both types of implants, sand-blasted, large grit, acid-etched (SLA) surfaced implants tended to have slightly less crestal bone loss compared to titanium plasma-sprayed (TPS) surfaced implants, but the difference was not significant (P > 0.30). Conclusion: The implant design with the shorter smooth coronal collar had no additional bone loss and may help to reduce the risk of an exposed metal implant margin in areas of esthetic concern.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据