期刊
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME
卷 127, 期 3, 页码 419-430出版社
ASME
DOI: 10.1115/1.1900139
关键词
-
Pressure drops and friction factors associated with the forced flow of de-ionized water over staggered and in-line circular/diamond shaped micro pin-fin bundles 100 mu m long with hydraulic diameter of 50 and 100 mu m have been experimentally investigated over Reynolds number ranging from 5 to 128. Pin fins were arranged according to two different horizontal and vertical pitch ratios (1.5 and 5). The applicability of conventional scale correlations to evaluate micro flow tests results has been assessed. It is shown that the available large-scale correlations do not adequately predict the pressure drop obtained at the micro scale. A modified correlation, based on the experimental results obtained using micro scale devices, has been proposed. The refined correlation accounts for fin density and the endwall effects encountered in micro scale configurations.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐