4.7 Article

Efficiency of the Ortho VITROS assay for detection of hepatitis C virus-specific antibodies increased by elimination of supplemental testing of samples with very low sample-to-cutoff ratios

期刊

JOURNAL OF CLINICAL MICROBIOLOGY
卷 43, 期 5, 页码 2477-2480

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.43.5.2477-2480.2005

关键词

-

向作者/读者索取更多资源

The clinical significance of specimens with low sample-to-cutoff (S/Co) ratios in the Ortho VITROS chemiluminescence assay (CIA) for detection of antibodies to hepatitis C virus (HCV) was evaluated. In one study of 482 CIA-reactive samples, none of the 83 samples with S/Co ratios of < 5 was HCV RNA positive. In a subsequent study, 332 samples with S/Co ratios of between 1 and 20 were tested with the recombinant immunoblot assay (RIBA). None of the 163 samples with S/Co ratios of < 5 was RIBA positive, 83% were RIBA negative, and 28 samples (18%) were RIBA indeterminate. HCV RNA and/or clinical evidence of hepatitis was not found in the 27 indeterminate cases examined. These results show that over 99% of samples with very low S/Co ratios (<= 5) have no evidence of HCV infection. Therefore, we suggest that the HCV antibody testing algorithm for the VITROS assay might be modified to eliminate supplemental testing of samples with very low S/Co ratios.