4.6 Article

High air flow, low pressure drop, bio-aerosol collector using a multi-slit virtual impactor

期刊

JOURNAL OF AEROSOL SCIENCE
卷 36, 期 5-6, 页码 619-638

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jaerosci.2004.12.010

关键词

virtual impactor; aerosol collector; bio-aerosol

向作者/读者索取更多资源

A bio-aerosol collector was developed comprising a low pressure drop, multi-slit virtual impactor, a wetted wall cyclone collector from Research International (RI), and associated plumbing and blowers. The collector is portable, samples air at 1220 L/min, provides 3-8 mL liquid sample, and has 70 W power consumption. The RI collector was selected for this unit following an evaluation of leading commercial aerosol collectors. The compact, multi-slit virtual impactor has an area of 334 cm(2) and a pressure drop of 0.2 kPa at an inlet flow of 1220 L/min. The virtual impactor reported here concentrates the aerosols by a factor of four when the major to minor flow is adjusted to 4:1 ratio, but it has been field operated at a ratio of 8: 1 when sampling at 2300 L/min. A preliminary evaluation of the RI-Lawrence Livermore National Laboratory collector was conducted to verify the unit has low pressure drop and can collect aerosols greater than 2 mu m. A more detailed evaluation is needed to fully characterize the collector. This bio-aerosol collector has been incorporated in autonomous pathogen detection systems. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据