Silver nanoparticle assemblies supported on glassy-carbon electrodes for the electro-analytical detection of hydrogen peroxide

期刊

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
卷 382, 期 1, 页码 12-21

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-005-3205-5

关键词

hydrogen peroxide; silver nanoparticles; glassy-carbon electrode; edge-plane pyrolytic-graphite electrode; oxygen reduction

向作者/读者索取更多资源

Electrochemical detection of hydrogen peroxide using an edge-plane pyrolytic-graphite electrode (EPPG), a glassy carbon (GC) electrode, and a silver nanoparticle-modified GC electrode is reported. It is shown, in phosphate buffer (0.05 mol L-1, pH 7.4), that hydrogen peroxide cannot be detected directly on either the EPPG or GC electrodes. However, reduction can be facilitated by modi. cation of the glassy-carbon surface with nanosized silver assemblies. The optimum conditions for modi. cation of the GC electrode with silver nanoparticles were found to be deposition for 1 min at -0.5 V vs. Ag from 5 mmol L-1 AgNO3/0.1 mol L-1 TBAP/MeCN, followed by stripping for 2 min at +0.5 V vs. Ag in the same solution. A wave, due to the reduction of hydrogen peroxide on the silver nanoparticles is observed at -0.68 V vs. SCE. The limit of detection for this modified nanosilver electrode was 2.0 x 10(-6) mol L-1 for hydrogen peroxide in phosphate buffer (0.05 mol L-1, pH 7.4) with a sensitivity which is five times higher than that observed at a silver macro-electrode. Also observed is a shoulder on the voltammetric wave corresponding to the reduction of oxygen, which is produced by silver-catalysed chemical decomposition of hydrogen peroxide to water and oxygen then oxygen reduction at the surface of the glassy-carbon electrode.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据