4.7 Article

Thin-film organic photodiodes as integrated detectors for microscale chemiluminescence assays

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 106, 期 2, 页码 878-884

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2004.10.005

关键词

organic photodiode; microchip; chemiluminescence; microfluidic

向作者/读者索取更多资源

We report the use of thin-film organic photodiodes, as integrated optical detectors for microscale chemiluminescence. The copper phthalocyanine-fullerene (CuPc-C-60) small molecule photodiodes have an external quantum efficiency of similar to 30% at 600-700 nm, an active area of 2 mm x 8 mm and a total thickness of similar to 2 mm. Simple detector fabrication, based on layer-by-layer vacuum deposition, allows facile integration with planar chip-based systems. To demonstrate the efficacy of the approach, CuPc-C-60 photodiodes were used to monitor a peroxyoxalate based chemiluminescence reaction (PO-CL) within a poly(dimethylsiloxane) (PDMS) microfluidic device. Optimum results were obtained for applied reagent flow rates of 25 mu L/min, yielding a CL signal of 8.8 nA within 11 min. Reproducibility was excellent with typical relative standard deviations (R.S.D.) below 1.5%. Preliminary quantitation of hydrogen peroxide yielded a detection limit of similar to 1 mM and linearity over at least three decades. With improved sensitivity and when combined with enzymatic assays the described integrated devices could find many applications in point-of-care diagnostics. (c) 2004 Elsevier B.V. All rights reserved.