4.8 Article

Energy and exergy analysis of a building integrated semitransparent photovoltaic thermal (BISPVT) system

期刊

APPLIED ENERGY
卷 96, 期 -, 页码 409-416

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2012.02.079

关键词

Building integrated photovoltaic thermal (BIPVT) system; Semitransparent PV module; Exergy analysis

向作者/读者索取更多资源

In this paper, a study has been carried out to evaluate the energy and exergy performance of a building integrated semitransparent photovoltaic thermal (BISPVT) system integrated to the roof of a room. Comparisons have been carried out on the basis of energy and exergy by considering six different photovoltaic (PV) modules. It is observed that maximum annual electrical energy is 810 kW h for heterojunction comprised of a thin amorphous silicon (a-Si) PV cell on top of a crystalline silicon (c-Si) cell (also known as HIT) and the maximum annual thermal energy is 464 kW h for a-Si. It is also concluded that HIT PV module is suitable for producing electrical power whereas a-Si is suitable for space heating. However, an annual overall thermal energy (2497 kW h) and exergy (834 kW h) is maximum for HIT PV module. (C) 2012 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据