4.2 Article

Investigation of an ozone membrane contactor system

期刊

OZONE-SCIENCE & ENGINEERING
卷 27, 期 3, 页码 209-217

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/01919510590945750

关键词

ozone; membranes; membrane reactors; ozone contactors; fine bubble diffusers; wastewater treatment; drinking water treatment; disinfection; oxidation

向作者/读者索取更多资源

Ozone mass transfer rates were determined for nine expanded porous Teflon membranes that had different pore size, thickness, and pore volume, a nonporous Teflon membrane, and a PVDF membrane. The mass transfer coefficient was 7.6 +/- 0.5 x 10(-5) m/s at Re of 2000 for all membranes tested even though pore sizes ranged from 0.07 to 6 mu m and thickness from 0.076 to 0.25 mm. Mass transfer increased with liquid side Reynolds number. Therefore, it is likely that ozone mass transfer is liquid phase controlling and not membrane limited. For a hypothetical case of 4000 m(3)/d and 2 mg/L ozone transferred, plate and frame membrane and hollow fiber contactors are approximately one and two orders of magnitude smaller, respectively, than fine-bubble diffusers.