4.5 Article Proceedings Paper

Use of molecule imprinting-chemiluminescence method for the determination of tamoxifen in breast cancer sufferers' urine

期刊

LUMINESCENCE
卷 20, 期 4-5, 页码 315-320

出版社

WILEY
DOI: 10.1002/bio.837

关键词

tamoxifen; soluble Mn(IV); molecule imprinting-chemiluminescence method

向作者/读者索取更多资源

The reaction between soluble Mn(IV) and tamoxifen can produce chemiluminescence and formaldehyde can enhance this chemiluminescence reaction. A tamoxifen molecular imprinted polymer (MIP) was synthesized and its adsorption selectivity to tamoxifen in aqueous solution was evaluated. Using a synthesized tamoxifen MIP as the recognition material and a soluble Mn(IV)-formaldehyde-tamoxifen chemiluminesence system as the detection system, a new molecule imprinting-chemiluminesence method of determination of tamoxifen was established. The response range of this method was 1.0 x 10(-7)- 6.0 x 10(-6) g/mL, with a linear correlation coefficient of 0.997. The detection limit was 4 x 10(-8) g/mL. The relative standard deviation for 5.0 x 10(-7) g/mL tamoxifen solution was 4.1% (n = 9). Copyright (c) 2005 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据