Indoor air microbiological evaluation of offices, hospitals, industries, and shopping centers

期刊

MEMORIAS DO INSTITUTO OSWALDO CRUZ
卷 100, 期 4, 页码 351-357

出版社

FUNDACO OSWALDO CRUZ
DOI: 10.1590/S0074-02762005000400003

关键词

indoor air; airborne microorganisms; principal components analysis; air sampler

向作者/读者索取更多资源

In this study it was compared the MAS-100 and the Andersen air samplers' performances and a similar trend in both instruments was observed. It was also evaluated the microbial contamination levels in 3060 samples of offices, hospitals, industries, and shopping centers, in the period of 1998 to 2002, in Rio de Janeiro city. Considering each environment, 94.3 to 99.4% of the samples were the allowed limit in Brazil (750 CFU/m(3)). The industries' results showed more important similarity among fungi and total heterotrophs distributions, with the majority of the results between zero and 100 CFU/m(3). The offices' results showed dispersion around 300 CFU/m(3). The hospitals' results presented the same trend, with an average of 200 CFU/m(3). Shopping centers' environments showed an average of 300 CFU/m(3) for fungi, but presented a larger dispersion pattern for the total heterotrophs, with the highest average (1000 CFU/m(3)). It was also investigated the correlation of the sampling period with the number of airborne microorganisms and with the environmental parameters (temperature and air humidity) through the principal components analysis. All indoor air samples distributions were very similar The temperature and air humidity had no significant influence on the samples dispersion patterns.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据