期刊
JOURNAL OF OCCUPATIONAL HEALTH
卷 47, 期 4, 页码 350-353出版社
JAPAN SOC OCCUPATIONAL HEALTH
DOI: 10.1539/joh.47.350
关键词
lead; respirable dust; blood lead
An environmental and biological monitoring of a lead acid battery manufacturing unit was carried out to measure the respirable particulate matter, lead content in working atmosphere and blood lead levels of workers employed in different sections. The results showed high mean air lead concentration in buffing (1444.45 mu g/m(3)), plate cutting (430.14 mu g/m(3)) and pasting (277.48 mu g/m(3)) sections. The mean blood lead levels of employees in these sections were also higher than the values prescribed by ACGIH.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐