期刊
SCIENCE OF THE TOTAL ENVIRONMENT
卷 347, 期 1-3, 页码 148-162出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.scitotenv.2004.12.032
关键词
dioxin; catalyst; activated carbon; stack sampling; incinerator
Partitioning of PCDD/F (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofirran) congeners between gaseous and particulate phases and removal efficiencies of the existing air pollution control devices (APCDs) for PCDD/Fs at two large-scale municipal waste incinerators (MWIs) in Taiwan are evaluated via stack sampling and analysis. Two MWIs investigated are equipped with activated carbon injection (ACI) and selective catalytic reduction system (SCR) as major PCDD/F control devices, respectively. The average PCDD/F concentrations of stack gases are 2.35 and 1.49 ng/N m(3), and the international toxic equivalent quantity (TEQ) are 0.17 and 0.043 ng TEQ/N m(3) in MWI-A and MWI-B, respectively. The average removal efficiency of PCDD/Fs achieved with ACI+BF (bag filters) reaches 95% (MWI-A) while that achieved with the WS (wet scrubber)+SCR system reaches 99% (MWI-B). The results obtained on gas/particulate partitioning in flue gases indicate that particulate-phase PCDD/Fs accounted for 27.7% and 24.7% of the total PCDD/F concentrations at the outlets of cyclone (CY) and electrostatic precipitator (EP) for MWI-A and MWI-B, respectively. But the gas/particulate partitioning in flue gas after PCDD/Fs control devices is quite different in two MWls. This study also indicates that total 2,3,7,8-substituted PCDD/F discharges are 142.3 mu g TEQ/ton waste for MWI-A and 98.6 mu g TEQ/ton waste for MWI-B, respectively. (c) 2004 Elsevier B.V All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐