4.7 Article

Alizarin violet modified carbon paste electrode for the determination of trace silver(I) by adsorptive voltammetry

期刊

TALANTA
卷 67, 期 1, 页码 28-33

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2005.02.009

关键词

adsorptive voltammetry; modified carbon paste electrode; silver; alizarin violet

向作者/读者索取更多资源

A sensitive and selective procedure for the determination of trace silver(l) at alizarin violet modified carbon paste electrode has been developed. Silver(l) was accumulated on the electrode surface via complex formation with modifier in 0.1 mol/L acetate buffer (pH 5.2). After electrochemical reduction of silver(I) had been carried out, the reoxidation wave of silver(0) appeared at 0.05 V (versus SCE) on scanning the potential in the positive direction in 0.1 mol/L H2SO4 + 2.0 x 10(-4) mol/L KBr. For a preconcentration time of 3 min, the detection limit is 1.0 x 10(-10) mol/L and the linear range is from 3.0 x 10(-10) to 1.2 x 10(-7) mol/L. Many coexisting metal ions have little or no effect on the determination of silver(l). The proposed method was applied to the determination of silver in waste water and zinc alloy samples with satisfactory results. (C) 2005 Elsevier B.V. All rights, reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据