4.6 Article Proceedings Paper

Molds in floor dust, building-related symptoms, and lung function among male and female schoolteachers

期刊

INDOOR AIR
卷 15, 期 -, 页码 7-16

出版社

WILEY-HINDAWI
DOI: 10.1111/j.1600-0668.2005.00352.x

关键词

indoor air; building related symptoms; Molds; lung function; bronchial challenge; nasal lavage; CO diffusion capacity

向作者/读者索取更多资源

Five hundred and twenty-two teachers from 15 public schools, eight 'water-damaged' schools, and seven 'non-damaged' schools with no visible water damage were included in a cross-sectional design. Mold growth was assessed by recording the amount of dust on the floor and in the air in classrooms and the content of a number of mold species in the dust (CFU/g dust). The evaluation of health symptoms included symptoms recorded by questionnaire and spirometry, bronchial challenge, and CO-diffusion capacity. Nasal lavage fluid was analyzed for IL-8 and ECP. Personal and psychosocial factors were included as confounders. In this study population mucus membrane irritation symptoms (MMI) and general symptoms were reported more frequently by women than by men with odds ratios ranging from 1.4 to 2.1. Women's reports of symptoms from mucous membranes and skin and general symptoms were positively associated with mold exposure. Odds ratio for 'difficult to concentrate' after adjustment for confounders was 11.2 (1.4-90.1, 95% CI) at high levels of mold exposure. None of the lung function tests performed in this study were associated with mold exposure, to the 'water damaged' vs. 'non-damaged' classification, or to the symptoms reported. IL-8 and ECP were not associated either.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据