4.7 Article

International and multicenter comparison of EUCAST and CLSI M27-A2 broth microdilution methods for testing susceptibilities of Candida spp. to fluconazole, itraconazole, posaconazole, and voriconazole

期刊

JOURNAL OF CLINICAL MICROBIOLOGY
卷 43, 期 8, 页码 3884-3889

出版社

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.43.8.3884-3889.2005

关键词

-

向作者/读者索取更多资源

The aim of this study was to compare MICs of fluconazole, itraconazole, posaconazole, and voriconazole obtained by the European Committee on Antibiotic Susceptibility Testing (EUCAST) and CLSI (formerly NCCLS) methods in each of six centers for 15 Candida albicans (5 fluconazole-resistant and 4 susceptibledose-dependent [S-DD] isolates), 10 C. dubliniensis, 7 C. glabrata (2 fluconazole-resistant isolates), 5 C. guilliermondii (2 fluconazole-resistant isolates), 10 C. krusei, 9 C. lusitaniae, 10 C. parapsilosis, and 5 C. tropicalis (1 fluconazole-resistant isolate) isolates. CLSI MICs were obtained visually at 24 and 48 h and spectrophotometric EUCAST MICs at 24 h. The agreement (within a 3-dilution range) between the methods was species, drug, and incubation time dependent and due to lower EUCAST than CLSI MICs: overall, 94 to 95% with fluconazole and voriconazole and 90 to 91% with posaconazole and itraconazole when EUCAST MICs were compared against 24-h CLSI results. The agreement was lower (85 to 94%) against 48-h CLSI endpoints. The overall interlaboratory reproducibility by each method was >= 92%. When the comparison was based on CLSI breakpoint categorization, the agreement was 68 to 76% for three of the four species that included fluconazole-resistant and S-DD isolates; 9% very major discrepancies (<= 8 mu g/ml versus >= 64 mu g/ml) were observed among fluconazole-resistant isolates and 50% with voriconazole (<= 1 mu g/ml versus >= 4 mu g/ml). Similar results were observed with itraconazole for seven of the eight species evaluated (28 to 77% categorical agreement). Posaconazole EUCAST MICs were also substantially lower than CLSI MIC modes (0.008 to 1 mu g/ml versus 1 to >= 8 mu g/ml) for some of these isolates. Therefore, the CLSI breakpoints should not be used to interpret EUCAST MIC data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据