期刊
COLOR RESEARCH AND APPLICATION
卷 30, 期 4, 页码 288-294出版社
WILEY
DOI: 10.1002/col.20124
关键词
color difference metrics; color matching; color measurement; color space; CIELAB; CIE94; CMC; CIEDE2000
Ninety-six nylon pairs were prepared, including red, yellow, green, and blue standards, each at two lightness levels with CIE94 Delta E units ranging from 0.15 to 4.01. Visual assessments of acceptability were carried out by 21 females. Logistic regression compared visual results to four color-difference equations, CIELAB, CMC, CIE94, and CIEDE2000. It was found that CMC most closely represented judgments of average observers. (c) 2005 Wiley Periodicals, Inc.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐