4.2 Article

A preliminary comparison of CIE color differences to textile color acceptability using average observers

期刊

COLOR RESEARCH AND APPLICATION
卷 30, 期 4, 页码 288-294

出版社

WILEY
DOI: 10.1002/col.20124

关键词

color difference metrics; color matching; color measurement; color space; CIELAB; CIE94; CMC; CIEDE2000

向作者/读者索取更多资源

Ninety-six nylon pairs were prepared, including red, yellow, green, and blue standards, each at two lightness levels with CIE94 Delta E units ranging from 0.15 to 4.01. Visual assessments of acceptability were carried out by 21 females. Logistic regression compared visual results to four color-difference equations, CIELAB, CMC, CIE94, and CIEDE2000. It was found that CMC most closely represented judgments of average observers. (c) 2005 Wiley Periodicals, Inc.