4.7 Article Proceedings Paper

Adding in vivo quantitative 1H MR spectroscopy to improve diagnostic accuracy of breast MR imaging:: Preliminary results of observer performance study at 4.0 T

期刊

RADIOLOGY
卷 236, 期 2, 页码 465-475

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2362040836

关键词

-

资金

  1. NCI NIH HHS [CA92004, P30 CA77398] Funding Source: Medline
  2. NCRR NIH HHS [RR00400, RR08079] Funding Source: Medline

向作者/读者索取更多资源

PURPOSE: To determine whether the addition of in vivo quantitative hydrogen 1 (H-1) magnetic resonance (MR) spectroscopy can improve the radiologist's diagnostic accuracy in interpreting breast MR images to distinguish benign from malignant lesions. MATERIALS AND METHODS: The study was approved by the institutional review board and, where appropriate, was compliant with the Health Insurance Portability and Accountability Act. All patients provided written informed consent. Fifty-five breast MR imaging cases-one lesion each in 55 patients aged 24-66 years with biopsy-confirmed findings-were retrospectively evaluated by four radiologists. Patients were examined with contrast material-enhanced fat-suppressed T1-weighted 4.0-T MR imaging. The concentration of total choline-containing compounds (tCho) was quantified by using single-voxel H-1 MR spectroscopy. For each case, the radiologists were asked to give the percentage probability of malignancy, the Breast Imaging and Reporting Data System category, and a recommendation for patient treatment. Two interpretations were performed for each case: The initial interpretation was based on the lesion's morphologic features and time-signal intensity curve, and the second interpretation was based on the lesion's morphologic features, time-signal intensity curve, and tCho concentration. Receiver operating characteristic (ROC), Wilcoxon signed rank, K statistic, and accuracy (based on the area under the ROC curve) analyses were performed. RESULTS: Of the 55 lesions evaluated, 35 were invasive carcinomas and 20 were benign. The addition of H-1 MR spectroscopy resulted in higher sensitivity, specificity, accuracy, and interobserver agreement for all four radiologists. More specifically, two of the four radiologists achieved a significant improvement in sensitivity (P = .03, P = .03), and all four radiologists achieved a significant improvement in accuracy (P = .01, P = .05, P = .009, P < .001). CONCLUSION: Current study results suggest that the addition of quantitative H-1 MR spectroscopy to the breast MR imaging examination may help to improve the radiologist's ability to distinguish benign from malignant breast lesions. (c) RSNA, 2005.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据