4.6 Article

Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications

期刊

MEDICAL PHYSICS
卷 32, 期 8, 页码 2487-2495

出版社

WILEY
DOI: 10.1118/1.1949749

关键词

organ deformation; 4D treatment planning; grid size; dose calculation

资金

  1. NCI NIH HHS [P01 CA59872] Funding Source: Medline

向作者/读者索取更多资源

In this study we investigated the accumulation of dose to a deforming anatomy (such as lung) based on voxel tracking and by using time weighting factors derived from a breathing probability distribution function (p.d.f.). A mutual information registration scheme (using thin-plate spline warping) provided a transformation that allows the tracking of points between exhale and inhale treatment planning datasets. (and/or intermediate state scans). The dose distributions were computed at the same resolution on each dataset using the Dose Planning Method (DPM) Monte Carlo code. Two accumulation/interpolation approaches were assessed. The first maps exhale dose grid points onto the inhale scan, estimates the doses at the tracked locations by trilinear interpolation and scores the accumulated doses (via the p.d.f.) on the original exhale data set. In. the second approach, the volume associated with each exhale dose grid point (exhale dose voxel) is first subdivided into octants, the center of each octant is mapped to locations on the inhale dose grid and doses are estimated by trilinear interpolation. The octant doses are then averaged to form the inhale voxel dose and scored at the original exhale dose grid point location. Differences between the interpolation schemes are voxel size and tissue density dependent, but in general appear primarily only in regions with steep dose gradients (e.g., penumbra). Their magnitude (small regions of few percent differences) is less than the alterations in dose due to positional and shape changes from breathing in the first place. Thus, for sufficiently small dose grid point spacing, and relative to organ motion and deformation, differences due solely to the interpolation are unlikely to result in clinically significant differences to volume-based evaluation metrics such as mean lung dose (MLD) and tumor equivalent uniform dose (gEUD). The overall effects of deformation vary among patients. They depend on the tumor location, field size, volume expansions tissue heterogeneity, and direction of tumor displacement with respect to the beam, and are more likely to have an impact on serial organs (such as esophagus), rather than on large parallel organs (such as lung). (c) 2005 American Association of Physicists in Medicine.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据