4.7 Article

Energy performance assessment of a window with a horizontal Venetian blind

期刊

ENERGY AND BUILDINGS
卷 37, 期 8, 页码 836-843

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2004.11.008

关键词

energy performance; Venetian blind; window

向作者/读者索取更多资源

This study examines the effects of the presence of a Venetian blind on the thermal performance of a window. The blind is positioned adjacent to the indoor surface of either a single or double glazed window and the coupled convection and radiation heat transfer problem is solved using a two-dimensional finite volume model. The numerical model is validated with published experimental and numerical results in the literature. The results show that the presence of a Venetian blind significantly improves the energy performance of a single and double glazed window. The blind reduces the overall heat transfer rate through the window by reducing the thermal radiation from the indoor glazing. The improved understanding of the benefits of Venetian blinds may lead to better designs of window/shading systems. (c) 2004 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据