3.8 Article

Rain/no-rain classification methods for microwave radiometer observations over land using statistical information for brightness temperatures under no-rain conditions

期刊

JOURNAL OF APPLIED METEOROLOGY
卷 44, 期 8, 页码 1243-1259

出版社

AMER METEOROLOGICAL SOC
DOI: 10.1175/JAM2263.1

关键词

-

向作者/读者索取更多资源

One of the goals of the Global Precipitation Measurement project, the successor to the Tropical Rainfall Measuring Mission (TRMM), is to produce a 3-hourly global rainfall map using several spaceborne microwave radiometers. It is important, although often difficult, to classify radiometer observations over land as either rain or no rain because background land surface conditions change significantly with time and location. In this study, a no-rain brightness temperature database was created to infer land surface conditions using simultaneous observations by TRMM Microwave Imager (TMI) and precipitation radar (PR) with a resolution of 1 month and 1 degrees latitude x 1 degrees longitude. This paper proposes new rain/no-rain classification (RNC) methods that use the database to determine the background brightness temperature. The proposed RNC methods and the RNC method developed for the Goddard profiling algorithm (GPROF; the standard rain-rate retrieval algorithm for TMI) are applied to all TMI observations for the entire year of 2000, and the results are evaluated against the RNC made by PR as the truth. The first method (M1) simply uses the average brightness temperature at 85-GHz vertical polarization [denoted as TB (85 V)] under no-rain conditions as the background brightness temperature at 85-GHz vertical polarization [denoted as TB, (85 V)]. The second method (M2) uses a regression equation between TB (85 V) and TB (22 V) under no-rain conditions from the database. Here, TB, (85 V) is calculated by substituting the observed TB (22 V) into the regression equation. The ratio of accurate rain detection by GPROF to all rain occurrences detected by PR was 59%. This ratio was 57% for M1 and 63% for M2. The ratio with the weight of the rain rate was 81% for M1 and 86% for M2; it was 80% for GPROF. These comparisons were made by setting a threshold using a constant coefficient k(0) to make the ratio of false rain detection to all no-rain occurrences detected by PR almost the same (approximately 0.85%) for all three methods. Further comparisons among the methods are made, and the reasons for the differences are investigated herein.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据