Low frequency impact sound transmission in dwellings through homogeneous concrete floors and floating floors

期刊

APPLIED ACOUSTICS
卷 72, 期 4, 页码 177-189

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apacoust.2010.11.006

关键词

Impact sound transmission; Low frequency

向作者/读者索取更多资源

An experimentally validated analytical model has been developed in order to investigate the effect on impact sound transmission at low frequencies of location of the impact, type of floor, edge conditions, floor and room dimensions, position of the receiver and room absorption. The model was developed in order to allow rapid repeated calculations necessary for a parametric survey, described in a companion paper. The analytical model uses natural mode analysis to predict the sound field generated in rectangular rooms by point sound sources and the point excitation of homogeneous rectangular plates with different edge conditions. A floor-room model of the sound field generated in a room by a vibrating floor also has been derived. Laboratory and in situ measurements confirm that the models can be used to estimate impact sound transmission at low frequencies. The approach applies to homogeneous simply supported base plates of uniform thickness with homogenous floating floors, which again were experimentally validated in the laboratory and in situ. Crown Copyright (c) 2010 Published by Elsevier Ltd. All rights reserved.