4.8 Article

Perfluorinated sulfonamides in indoor and outdoor air and indoor dust: Occurrence, partitioning, and human exposure

期刊

ENVIRONMENTAL SCIENCE & TECHNOLOGY
卷 39, 期 17, 页码 6599-6606

出版社

AMER CHEMICAL SOC
DOI: 10.1021/es048340y

关键词

-

向作者/读者索取更多资源

Perfluorinated alkyl sulfonamides (PFASs) which are used in a variety of consumer products for surface protection were investigated through a comprehensive survey of indoor air, house dust, and outdoor air in the city of Ottawa, Canada. This study revealed new information regarding the occurrence and indoor air source strength of several PFASs including N-methylperfluorooctane sulfonamido-ethanol (MeFOSE), N-ethylperfluorooctane sulfonamidoethanol (EtFOSE), N-ethylperfluorooctane sulfonamide (EtFOSA), and N-methylperfluorooctane sulfonamidethylacrylate (MeFOSEA). Passive air samplers consisting of polyurethane foam disks were calibrated and used to conduct the indoor and outdoor survey. Indoor air concentrations for MeFOSE and EtFOSE (1490 and 740 pg m(-3), respectively) were about 10-20 times greater than outdoor concentrations, establishing indoor air as an important source to the outside environment. EtFOSA and MeFOSEA concentrations were lower in indoor air (40 and 29 pg m(-3) respectively) and below detection in outdoor air samples. For indoor dust, highest concentrations were recorded for MeFOSE and EtFOSE with geometric mean concentrations of 110 and 120 ng g(-1), while concentrations for EtFOSA and MeFOSEA were below detection and 7.9 ng g(-1) respectively. MeFOSE and EtFOSE concentrations in house dust followed levels in indoor air. However, resolution of the coupled air and dust data (for the same homes) was not successful using existing K-OA-based models for surface air exchange. The partitioning to house dust was greatly underpredicted. The difficulties with existing models may be due to the high activity coefficient of PFASs in octanol and/or a situation where the dust is greatly oversaturated with respect to the air due to components of the dust being contaminated with PFASs. A human exposure assessment based on median air and dust concentrations revealed that human exposure through inhalation (100% absorption assumed) and dust ingestion were similar to 40 and similar to 20 ng d(-1), respectively. However, for children the dust ingestion pathway was dominant and accounted for similar to 44 ng d(-1).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据