Comparison of nasal pressure transducer and thermistor for detection of respiratory events during polysomnography in children

期刊

SLEEP
卷 28, 期 9, 页码 1117-1121

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/sleep/28.9.1117

关键词

sleep; children; sleep-disordered breathing; transducer; thermistor

资金

  1. NHLBI NIH HHS [R01 HL062373] Funding Source: Medline

向作者/读者索取更多资源

Study Objectives: The results of small studies have suggested that a nasal-cannula pressure transducer has a higher sensitivity than a thermistor in detecting hypopneas and diagnosing sleep-disordered breathing in both adults and children. We compared a thermistor alone, and in conjunction with a pressure transducer, for detection of sleep-disordered breathing in children during in-home polysomnography. Design: Retrospective analysis of a subsample of a prospective cohort study. Setting: Students attending elementary school in the Tucson Unified School District. Participants: A subsample of the Tucson Children's Assessment of Sleep Apnea study population. Measurements and Results: Polysomnographic recordings of 40 children (24 girls and 16 boys, mean age 9.2 +/- 1.7 years; range 6-11 years) were analyzed to compare the detection of sleep-disordered breathing events by 2 different methods of measuring airflow: thermistor alone and thermistor with nasal-cannula pressure transducer (transducer) used simultaneously. The transducer detected all the respiratory events detected by the thermistor, but the thermistor detected only 84 % of the transducer-defined events. Consequently, the transducer-derived mean respiratory disturbance index was higher than that detected by the thermistor (7.0 +/- 3.8 vs 5.9 +/- 3.4, P < .001). The bias error between transducer respiratory disturbance index and thermistor respiratory disturbance index on a Bland-Altman plot was 1.08 (95 % confidence interval, 0.8-1.4). There was good agreement between the thermistor and the transducer for making the diagnosis of sleep apnea using a cutoff of a respiratory disturbance index greater than 5 (K = 0.69). The quality of the tracings with the transducer was comparable to that of the thermistor, but the transducer dislodged more frequently. Conclusion: The use of a nasal transducer in conjunction with a thermistor was more sensitive than the thermistor alone in detecting sleep-disordered breathing in children during unattended polysomnography.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据