4.5 Article

Intraobserver and interobserver reproducibility of ovarian volume, antral follicle count, and vascularity indices obtained with transvaginal 3-dimensional ultrasonography, power Doppler angiography, and the virtual organ computer-aided analysis imaging program

期刊

JOURNAL OF ULTRASOUND IN MEDICINE
卷 24, 期 9, 页码 1279-1287

出版社

AMER INST ULTRASOUND MEDICINE
DOI: 10.7863/jum.2005.24.9.1279

关键词

ovary; reproducibility; 3-dimensional power Doppler angiography; 3-dimensional ultrasonography; vascularity indices; Virtual Organ Computer-Aided Analysis

向作者/读者索取更多资源

Objectives. The purpose of this study was to assess intraobserver and interobserver reproducibility of the parameters of ovarian response and oocyte ability, studied by 3-dimensional ultrasonography and power Doppler angiography (PDA), and the possible influence of the ovarian functional stage. Methods. Twenty-nine women were included in an in vitro fertilization program. Fourteen women were evaluated after pituitary suppression (basal group), and 15 were scanned on the human chorionic gonadotropin administration day, after gonadotropin ovarian stimulation (stimulated group). A first observer acquired 2 volumes for each ovary. Another observer performed a second analysis of the volumes acquired by the first observer. We analyzed ovarian volume, follicle number in the basal group, vascularization index, flow index, and vascularization-flow index. The volumes were processed by the Virtual Organ Computer-Aided Analysis imaging program using plane A and 15 degrees rotational steps. Results. Ovarian volume showed excellent intraobserver and interobserver agreement, with an intraclass correlation coefficient (Intra-CC) and an interclass correlation coefficient (inter-CC) close to the unit. The Intra-CC and Inter-CC about the number of follicles were 0.964 and 0.978, respectively Vascularity indices showed an Intra-CC greater than 0.90. The vascularization index and the vascularization-flow index showed higher interobserver than intraobserver reproducibility (inter-CC > 0.96 for both). The flow index Inter-CC was 0.898. The reproducibility differences between the basal and stimulated ovary measurements were not significant. Conclusions. There is an excellent intraobserver and interobserver reproducibility of the ovarian volume, follicle counts, and 3-dimensional PDA indices. The ovarian functional stage has no influence on the reliability. Three-dimensional ultrasonography and PDA improve the study of ovarian parameters, and their reliability impels a change in the current clinical routine of performing and interpreting ultrasonography. Key words: ovary; reproducibility; 3-dimensional power

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据